Eagle Tree Systems eLogger V4 150A w/Wire Leads

Tower Stock# LXAVCW  •  Manufacturer Stock# MPRV4-LEADS-150
Eagle Tree Systems eLogger V4 150A w/Wire Leads (large view)
Regularly Purchased Together
Although customers also purchased these, compatibility is not guaranteed. Click an item for product details.

Notes from our tech department:
This is the 150 amp e-Logger V4 On-Board Data Logger from Eagle Tree Systems.

FEATURES

Great for planes, helis, car, trucks and boats
Accepts optional inexpensive sensors for GPS, temperature, RPM
(brushless, magnetic or optical) airspeed, altitude, servo current
and more
Logs throttle movement with optional Y-cable
Four times the memory capability of the V2
Current measured with a true Hall Effects sensor-not a resistance
shunt that creates heat and robs power from the system
Fully compatible with Windows Vista, 98SE, ME, Win2K and XP
USB live mode support displays info from the model live on the bench
on modeler's PC
All data is logged to permanent memory, which retains data even when
power is removed, adjustable logging rate (1-10 samples/second)
and lossless data compression for long log times
State of the art Windows virtual playback display and graphing
Internet updatable firmware
One year limited warranty

INCLUDES

150 amp e-Logger V4 On-Board Data Logger and USB cable

REQUIREMENTS

Installation and setup

SPECIFICATIONS

Voltage Measurement: Approx 5V to 70V
Voltage Resolution: Approx 0.02V
Current Measurement: up to 100 Amps, (150 Amps with the
MPRV3-LEADS-150)
Current Resolution: approx 0.02 Amps (0.035 Amps with the
MPRV3-LEADS-150)
Current Draw: Approx 30 mA with no sensors
Weight: Unit with Integrated Connectors: 0.9 oz (25 grams)
Temperature: Dual inputs, 0 F to 424 F (three temp inputs)
RPM Range: Approx 100 RPM to 50,000+ RPM
Units of Measure Supported: English and Metric
Size: Approx 2.25" x 1" x 0.5" (57mm x 28mm x 13mm) including sensor
pins
Length of Wires: Approx 2.5" (65mm)
Record Time: Varies with sample rate, parameters being recorded, and
"activeness" of model. Anywhere from around 45 minutes to many
hours is attainable depending on these settings.